Extended-Phase-Shift Control of Isolated Bidirectional DC–DC Converter for Power Distribution in Microgrid

IEEE Transactions on Power Electronics · 2011 · Vol. 27(11) · pp. 4667–4680
Biao ZhaoQingguang YuWeixin Sun

Abstract

This paper points out a phenomenon of power backflow in traditional phase-shift (TPS) control of isolated bidirectional full-bridge DC–DC converter (IBDC), and analyzes the effects which backflow power act on power circulating flow and current stress. On this basis, the paper proposes a novel extended-phase-shift (EPS) control of IBDC for power distribution in microgrid. Compared with TPS control, EPS control not only expands regulating range of transmission power and enhances regulating flexibility, but also reduces current stress and improves the system efficiency. The operation principle of EPS control and the operation modes of IBDC are analyzed in the paper. By establishing mathematical models of transmission power, backflow power, and current stress, the paper comparatively analyzes control performances of TPS and EPS control. At last, experimental results verify the excellent performance of EPS control and correctness of the theoretical analysis.

Microgrid Control and OptimizationAdvanced DC-DC ConvertersMultilevel Inverters and ConvertersBackflowPower (physics)Control theory (sociology)Power controlEngineeringMicrogridPower transmissionElectronic engineeringTransmission (telecommunications)Computer science
Citations
884
FWCI
26.27
field-weighted impact
References
26
Percentile
100%
vs. same field & year
Citations per year
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.