article Open AccessTop 1% cited
Golden‐angle radial sparse parallel MRI: Combination of compressed sensing, parallel imaging, and golden‐angle radial sampling for fast and flexible dynamic volumetric MRI
Magnetic Resonance in Medicine · 2013 · Vol. 72(3) · pp. 707–717
Li Feng✉(New York University)Robert Grimm(Friedrich-Alexander-Universität Erlangen-Nürnberg)Kai Tobias Block(New York University)Hersh Chandarana(New York University)Sungheon Kim(New York University)Jian XuLeon Axel(New York University)Daniel K. Sodickson(New York University)Ricardo Otazo(New York University)
Abstract
The high performance and flexibility provided by iGRASP can improve clinical studies that require robustness to motion and simultaneous high spatial and temporal resolution. Magn Reson Med 72:707-717, 2014. © 2013 Wiley Periodicals, Inc.
Advanced MRI Techniques and ApplicationsAdvanced Neuroimaging Techniques and ApplicationsMRI in cancer diagnosisDynamic imagingComputer scienceDynamic contrast-enhanced MRICompressed sensingReal-time MRITemporal resolutionIterative reconstructionImage resolutionRobustness (evolution)Computer vision
MeSH terms
AbdomenAdultBreast DiseasesChild, PreschoolContrast MediaFemaleHead and Neck NeoplasmsHumansImage EnhancementImage Interpretation, Computer-AssistedLiver DiseasesMagnetic Resonance ImagingMaleMiddle AgedTuberous Sclerosis
Funding
- National Institutes of Health
Citations
704
FWCI
26.48
field-weighted impact
References
44
Percentile
100%
vs. same field & year
Citations per year
References
Updating quasi-Newton matrices with limited storage
Mathematics of Computation · 1980 · 2,667 citations
Sparse MRI: The application of compressed sensing for rapid MR imaging
Magnetic Resonance in Medicine · 2007 · 6,856 citations
Generalized autocalibrating partially parallel acquisitions (GRAPPA)
Magnetic Resonance in Medicine · 2002 · 5,259 citations
k‐t FOCUSS: A general compressed sensing framework for high resolution dynamic MRI
Magnetic Resonance in Medicine · 2008 · 676 citations
Undersampled radial MRI with multiple coils. Iterative image reconstruction using a total variation constraint
Magnetic Resonance in Medicine · 2007 · 804 citations
Robust uncertainty principles: exact signal reconstruction from highly incomplete frequency information
IEEE Transactions on Information Theory · 2006 · 15,629 citations
<i>k‐t</i> BLAST and <i>k‐t</i> SENSE: Dynamic MRI with high frame rate exploiting spatiotemporal correlations
Magnetic Resonance in Medicine · 2003 · 793 citations
An Optimal Radial Profile Order Based on the Golden Ratio for Time-Resolved MRI
IEEE Transactions on Medical Imaging · 2007 · 698 citations
Citation Network
How this paper connects to the literature. Drag to explore, click any node to open that paper.