Scinovex
review Open AccessTop 1% cited

Polymer gel dosimetry

Physics in Medicine and Biology · 2010 · Vol. 55(5) · pp. R1–R63
Clive BaldockYves De DeeneSimon DoranG IbbottAndrew JirasekMartin LepageKimberley B. McAuleyMark OldhamL J Schreiner

Abstract

Polymer gel dosimeters are fabricated from radiation sensitive chemicals which, upon irradiation, polymerize as a function of the absorbed radiation dose. These gel dosimeters, with the capacity to uniquely record the radiation dose distribution in three-dimensions (3D), have specific advantages when compared to one-dimensional dosimeters, such as ion chambers, and two-dimensional dosimeters, such as film. These advantages are particularly significant in dosimetry situations where steep dose gradients exist such as in intensity-modulated radiation therapy (IMRT) and stereotactic radiosurgery. Polymer gel dosimeters also have specific advantages for brachytherapy dosimetry. Potential dosimetry applications include those for low-energy x-rays, high-linear energy transfer (LET) and proton therapy, radionuclide and boron capture neutron therapy dosimetries. These 3D dosimeters are radiologically soft-tissue equivalent with properties that may be modified depending on the application. The 3D radiation dose distribution in polymer gel dosimeters may be imaged using magnetic resonance imaging (MRI), optical-computerized tomography (optical-CT), x-ray CT or ultrasound. The fundamental science underpinning polymer gel dosimetry is reviewed along with the various evaluation techniques. Clinical dosimetry applications of polymer gel dosimetry are also presented.

Advanced Radiotherapy TechniquesRadiation Therapy and DosimetryMedical Imaging Techniques and ApplicationsDosimeterDosimetryMaterials scienceImaging phantomBrachytherapyMedical physicsNuclear medicineAbsorbed doseRadiochemistryIrradiation

MeSH terms

Diagnostic ImagingGelsHumansPolymersRadiometryRadiotherapyReproducibility of Results
Citations
862
FWCI
63.96
field-weighted impact
References
234
Percentile
100%
vs. same field & year
Citations per year
Cited by
Dosimetry tools and techniques for IMRT
Medical Physics · 2011 · 451 citations
References
Evaluation of the gamma dose distribution comparison method
Medical Physics · 2003 · 748 citations
Relaxation Effects in Nuclear Magnetic Resonance Absorption
Physical Review · 1948 · 6,454 citations
Introduction to radiation chemistry
Environment International · 1991 · 1,744 citations
The science and technology of gelatin
Journal of Colloid and Interface Science · 1978 · 706 citations
Citation Network

How this paper connects to the literature. Drag to explore, click any node to open that paper.

Polymer gel dosimetry · Scinovex